5CE / PB
15.06.2009
ReleaseNotes EVS300 SW Release 4.0
5202.6116.00
Page:7 of 13
Functionality:
- Autorepeat on keyboard:
CR 62: with Keyboard-controller software 2.20 installed, keys like UP and DOWN now offer
autorepeat
- Boot on power up:
CR 214: when selected in Setup, EVS300 now automatically boots when device is powered.
This is essential for remote controlled devices in flight inspection systems.
This also requires Keyboard Controller Software 2.20.
- Inventory
Release number is displayed
Bugfixes and Improvements:
- CR209: Inhibit LLZ measurements on GS frequencies and vice versa
When entering a GS frequency (320 .. 340MHz) the measurement mode automatically
changes to GS. On LLZ frequencies (108 .. 112MHz) only the LLZ setting is possible. This
avoids incorrect measurements.
- CR128: when measuring with changing level (e.g. fading), the AGC adjustment is causing
problems. à an increased hysteresis helps to improve the AGC behaviour
- CR219: in Attenuator Mode “AUTO” the switching between LN, LD and NORM is optimized
- CR215: Autocal also measures the IF2-filter. This is taken into account when measuring the
VOR 9960Hz Modgrade, resulting in an increased accuracy
- CR213: in remote STREAM the startflag is set correctly, or can be triggered with the
MARKSTREAM command
- CR212: Remote command to change between “big” and “normal” view
- CR211: remote command to set the units
- CR210: GPS longitudes with 3 digits cannot be displayed (reported from Korea) à fixed
- CR200: Datalogger Graph view is not working with empty lists à fixed
- CR195: Datalogger Graph: volume bargraph is not working à fixed
- CR194: Datalogger: Default selection can be restored
- CR 184: ILS DDM Indicator GS: +/-800µA
- CR180: Webinterface can be deactivated in Setup
- CR177: Measurement time VOR+MB is limited to 30ms, because lower values does not
make any difference anyway
- CR161: Autocal: When pressing “Clear Cal Values” the status remains “valid” à fixed
- CR155: GPS directions N,E,S,W are not saved à fixed
- Improved accuracy for ILS SDM measurements
Comentarios a estos manuales