Vista de pagina 51
VOR/ILS Analyzer EVS200
0796.1800.02 E-8 43
Chapter 3: Operation
Command AF8
command function
AF8 <AF-frequency ID> AF-frequency ID query
The command AF8 reads the actual AF frequency (ID) in the ILS /VOR mode.
Prediction for reading out the data of the corresponding mode (VOR/ILS) is the
switching over to display2.
Example:
command from the controller
response of the VOR/ILS Analyzer EVS200
query:
AF8 <CR>
af8 <CR>
e.g. 1020.0Hz <CR/LF>
e.g.. 1020.0Hz <CR/LF>
Command AM8
command function
AM8 <AM-modulation depth (ID)> query of AM-modulation depth (ID)
The command AM8 reads the actual AM-modulation depth (ID) in the ILS / VOR mode.
Prediction for reading out the data of the corresponding mode (VOR/ILS) is the
switching over to display2.
Example:
command from the controller
response of the VOR/ILS Analyzer EVS200
query:
AM8 <CR>
am8 <CR>
e.g. 10.0% <CR/LF>
e.g. 10.0% <CR/LF>
Command AM9
command function
AM9 <AM-modulation depth (voice)> query of AM-modulation depth (voice)
The command AM9 reads the actual AM-modulation depth (voice 300 Hz to 3kHz) in the ILS / VOR
mode.
Prediction for reading out the data of the corresponding mode (VOR/ILS) is the
switching over to display2.
Example:
command from the controller
response of the VOR/ILS Analyzer EVS200
query:
AM9 <CR>
am9 <CR>
e.g. 09.6% <CR/LF>
e.g. 09.6% <CR/LF>
Vista de pagina 51